Frequently asked questions
Troubleshooting answers from the CEE support team, grouped by product. Can't find what you need? Send us a support request.
General support
The product and serial number, the firmware and software versions, what you were doing when the problem started and any error shown. Include the cables, transducer, power source and GNSS or data collector you’re using, so we can assess the whole setup.
It’s printed on the product identification label. On a CEESCOPE™ it’s in the white identification box on the left-hand side of the front panel. Include it whenever you contact support: firmware compatibility varies between product generations.
From the Downloads page, including CEE-LINE Connect and CEESCOPE Connect. Some firmware is specific to your hardware or serial number, so support supplies it directly.
Listen to it out of the water: a working transducer clicks continuously as it pings. In Auto mode the echo sounder keeps adjusting ping power, so a click that gets louder and quieter is normal. A transducer that goes completely silent points to a connection or cable problem.
If you can, swap one part at a time. If the echo sounder works with a different transducer, the original transducer or its cable is the likely cause. Also check connectors for bent or rotated pins, dirt and water.
Yes, But not all the time. Damage close to the transducer head usually can’t be repaired, and water that has entered the cable can corrode it further along. A transducer causing problems on two different echo sounders is better replaced.
Yes. In one case a consistent 15–17 cm error on one channel was traced to an adapter cable; replacing it brought both channels back within 1–2 cm.
Contact support first so we can troubleshoot remotely. If it needs to come back, we’ll arrange a return and may ask for the cables, transducer and power source you were using as well.
CEE-LINE HD™
It depends on the controller: USB for Windows controllers such as the Trimble TSC7, combo cables for the TSC3, Topcon and Leica CS15 / CS20, and the Bluetooth cable for the TSC5 and Android collectors. The CEE-LINE USB Cable Options survey note covers every combination.
The high-speed USB-A cable carries the full 1,600-sample echogram and creates two COM ports, so two programs can use the data at once (for example CEE-LINE Connect 3 and your survey software). The programming cable is a single RS-232 virtual COM port with a lower-resolution echogram.
Another program probably has it open. With the single-port programming cable, close CEE-LINE Connect before connecting HYPACK, Hydromagic or other acquisition software.
When sending the echogram over the programming cable’s RS-232 link, set the maximum, 115,200 bps, in both the CEE-LINE and your software.
Yes. On some Trimble setups, USB powers the CEE-LINE while depths go to the controller over the DB9 serial connection.
Bluetooth needs firmware 3.2.0 or later on V3.x hardware. CEE-LINE units sold before August 2022 aren’t compatible. CEE-LINE Connect doesn’t need updating for the Bluetooth cable.
Yes, in testing with a TSC5, Trimble Access displayed and recorded both depths. Use the CEESTAR output format for dual frequency.
The high-speed USB cable and current firmware. The same firmware update unlocks dual frequency and the 20 Hz ping rate on supported units.
Use the USB programming cable; the USB data / power cable can’t update firmware. Check your serial number with support first, because the right firmware depends on the hardware generation, and older units may already have the newest firmware their hardware supports. Set the baud rate to 9600 before starting the update. On V3.x units, firmware 3.2.0 or later adds Bluetooth cable support.
That was a display bug in an early version of CEE-LINE Connect 3. Update to the latest version.
Check the power supply or power bank, and look for damage on the power / data cable and connectors. Try a different USB port or cable. If unplugging and reconnecting the USB brings it back, note how often it happens and contact support with your cable, power source and controller details.
By USB; no RS-232 connection is needed. The T10 runs Windows, so first check that Windows creates a COM port and that CEE-LINE Connect can talk to the CEE-LINE, then set up Trimble Access. Use the programming cable or the USB data / power cable.
With the Leica data / power combo cable, with the CEE-LINE powered from an external USB supply.
NMEA DBT is depth below the transducer, and NMEA DBS is depth below the surface; both are plain ASCII sentences. The CEE format is much richer: it adds the acoustic data, so use it when your software needs the echogram, not just a depth.
Yes, it can change the reported depth, not just the display; the exact effect depends on the output format and firmware. Firmware 3.0.2 and later apply both draft and index correctly to the CEE-format output.
Yes. It’s powered externally rather than by a battery, and it has streamed depths continuously for 60 hours in testing. It isn’t rated as an unattended permanent monitoring system, so talk to us about long-term installations.
CEESCOPE™
- Check the test depth is within the MAX DEPTH setting.
- Check the HF / LF and transducer settings match the transducer fitted.
- Check the transducer cable and LEMO connector: pins can rotate inside the barrel and stop lining up.
- Try a different transducer if you have one.
- Create a system report and send it to support.
Insert a USB drive, go to the System 3 screen, select Create system report and press Apply. Then select Export system report and press Apply again. Send us the system_files folder copied to the USB drive.
Yes, a 12 V or 24 V battery. Lithium batteries are lighter and give more run time.
The percentage only shows when no external power is connected. With external power it shows EXT or CHG.
Use a good-quality drive: some cheaper sticks have caused gaps in the USB copy, and a SanDisk SDCZ880-128G tested well. Log to internal memory and USB at the same time, so the internal 128 GB copy is complete even if the USB drive has a problem.
Check the receiver’s ZDA output. A receiver sending ZDA at 5 Hz but repeating the same timestamp five times caused problems; setting ZDA to 1 Hz fixed it.
Check the GNSS screen for the number of satellites and the fix quality, and watch the GGA sentences in your survey software. With NTRIP, confirm the corrections are arriving, and pick a specific mount point rather than an “auto” or “nearest” one.
The membrane over the buttons can lose its click. If a button stays depressed or stops responding, contact support; the front-panel membrane may need replacing.
First check your unit has dual frequency activated; we can confirm from the serial number. Activation is a hardware / licence option, not just a menu setting. Once it’s activated, enable the low frequency channel in the echo sounder settings and connect a dual frequency transducer.
The CEESCOPE uses UTC internally for survey data, with a UTC / local offset in the System settings. Don’t set the clock itself to local time: one unit set that way went back to UTC after a few days. Set the time to suit your GNSS and processing workflow.
Try the supplied AC adapter or another suitable power source. If it still won’t charge, create a system report and send it to support. The cause can be the charging hardware as well as the battery, so the unit may need assessing.
Contact support first. Internal power and charging problems are handled as a service job.
CEE ECHO™
Any receiver that outputs NMEA 0183, by Bluetooth or cable. Customers use Trimble and Emlid receivers among others.
Yes. We can supply a direct cable for Trimble R-series receivers, including the R10.
By Bluetooth: pair the receiver with the CEE ECHO and it receives NMEA from the Reach over that link. We also make an external GNSS cable for Emlid receivers if you’d rather use a wire.
Recent Emlid firmware changed its Bluetooth behaviour, especially while the receiver is also getting NTRIP corrections through a phone. Use the Emlid GNSS cable, or contact support with your Emlid firmware version.
The position comes from your receiver, so the CEE ECHO gets RTK if your receiver has an RTK fix.
CEESCOPE Connect, the same software as the CEESCOPE™, over Ethernet from a PC.
Check the IP settings, that you’re using the right Ethernet port on a computer with more than one, and that Windows Firewall isn’t blocking the connection.
It depends on the order. It can be supplied on its own if you already have a suitable transducer, or as a complete system with transducer and mounting hardware.
Note the serial number and any error on screen and contact support. Don’t assume the cause: fixes depend on the unit and firmware, and some need a specific firmware update.
Don’t keep retrying with the same file: firmware has to match the hardware revision. If the unit still runs, check its firmware version on the system information screen and send it to support with the serial number.
Run the bar check routine on the touchscreen (no PC needed) against a known reference, and make sure sound velocity, draft and index are set correctly, as they all affect the depth.
CEETIDE MAX™
Through its web interface over Ethernet, or from anywhere via a VPN device such as a Tosibox router.
CSV.
Several years of tide logs. Raw GNSS files are much larger, so logging raw GNSS shortens that.
Yes, with battery power, solar charging and remote internet access. The battery and solar panel are sized for the autonomy and communications you need, with LiFePO4 or gel lead-acid options. The Rapid Deployment Kit is the ready-built version.
Yes. The reference setup combines the gauge, a surface-mounted probe and a GNSS antenna, relating the measured water level to the local tide datum and ellipsoidal height.
Two ways: from a USB drive at the unit, or remotely through the web server. Keep power on throughout either way.
From a USB drive:
- Format a USB drive as NTFS or FAT32 and copy the firmware file (CTMFW_X.Y.Z.bin) to its root.
- Insert it into the control unit, press DISPLAY and unlock the screen if needed.
- Wait for the USB button to turn solid blue, then go to MENU → SYSTEM.
- On System 4/5 (Control), select FW Update, check the filename and choose Apply firmware update.
- When the Home screen returns, check the new version under About.
Through the web server (for example over a Tosibox connection):
- Log in with an ADMIN account and open the CEETIDE MAX: System page.
- Upload the firmware file and confirm the update.
- Stay on the progress page until it finishes, then check the version on the About page.
For Tosibox, give the CEETIDE MAX™ a static IP on the same subnet as the Tosibox LAN (for example Tosibox 192.168.3.1, gauge 192.168.3.53).
CEE JET™
Jet skis vibrate a lot. Check the hardware before each use, re-tighten fasteners regularly, and use lock nuts or thread locker where specified.
Software
No. GNSS field software (Trimble Access, Carlson SurvCE, Leica Captivate, Topcon MAGNET Field) logs a depth with every point. Use HYPACK®, Hydromagic or BeamworX if you want every sounding and the recorded echogram.
No. The GNSS receiver and the CEE-LINE can each connect to the laptop, and Hydromagic combines depth and position. Set the receiver to stream NMEA 0183.
Yes. One customer setup used a Sena Parani Bluetooth radio to send CEE-LINE depths to a laptop on shore.
Yes. HYPACK®, Hydromagic and Mission Planner all read MAVLink .waypoints files, and mission lines have been imported into HYPACK®. Hydromagic has also sent routes to the CEE-USV and shown it on the map.
Hydromagic has corrected variable GNSS-to-depth latency in one field case. Corrections like this change results, so check them carefully, and contact support if you see it.
Yes. We’ve run Hydromagic training on data collection and editing, and hosted Australian HYPACK® user workshops covering single beam and multibeam.
Older products
The CEEPULSE is end of life. The CEE-LINE™ is its replacement.
Look for cable damage, dirty or corroded connectors and a damaged O-ring. You can test basic functions in CEEPULSE CONNECT over Bluetooth or the supplied cable.
No. The original 200 kHz transducer hasn’t been made for about 15 years, and the similar-looking Airmar SS510 isn’t compatible. The CEESCOPE™ replaced the CEEDUCER™ range; if you already have a GNSS rover, the CEE-LINE™ is a lower-cost option.
Often, yes. A firmware update adds dual frequency and the 20 Hz ping rate, and the high-speed USB cable gives the full echogram. Bluetooth needs V3.x hardware (units sold from August 2022). Send us your serial number to check.
Talk to the CEE support team
Send the product, serial number, firmware version and what you were doing when the problem started, and we'll get back to you.